Koppel Super Inverter AC Error Codes;

Error Code | Problem |
---|---|
E0 | Indoor unit EEPROM parameter error |
E1 | Indoor / outdoor units communication error |
E2 | Zero-crossing signal error |
E3 | Indoor fan speed has been out of control |
E4 | Open circuit or short circuit of indoor room temperature T1 |
E5 | Open circuit or short circuit of evaporator coil temperature T2 sensor |
EC | Refrigerant Leakage Detection |
F1 | Open circuit or short circuit of outdoor ambient T4 temperature sensor |
F2 | Open circuit or short circuit of condenser coil temperature T3 sensor |
F3 | Open circuit or short circuit of compressor discharge T5 temperature sensor |
F4 | Outdoor unit EEPROM parameter error |
F5 | Outdoor fan speed has been out of control |
P0 | IPM malfuntion of IGBT over-strong current protection |
P1 | Over voltage or over low voltage protection |
P2 | High temperature protection of compressor top diagnosis and solution |
P4 | Inverter compressor drive sensor |
EEPROM parameter error diagnosis and solution E0/F4:

Error Signals On The Display
In case of error, the display on the indoor unit shown the following error codes
Error Code: E 1
RUN lamp: flashes once
Description of the trouble: The fault of indoor temperature sensor
Error Code: E 2
RUN lamp: flashes twice
Description of the trouble: The fault of indoor pipe temperature sensor
Error Code: E 6
RUN lamp: flashes 6 times
Description of the trouble: Malfunction of indoor fan motor.

Koppel AC Troubleshooting
Malfunction: The appliance does not operate
Possible Causes:
- Power failure/plug pulled out
- Damaged indoor/outdoor unit fan motor
- Faulty compressor thermomagnetic circuit breaker
- Faulty protective device or fuses.
- Loose connections or plug pulled out
- It sometimes stops operating to protect the appliance.
- Voltage higher or lower than the voltage range
- Active TIMER-ON function
- Damaged electronic control board
Malfunction: Strange odour
Possible Causes: Air filter dirty
Malfunction: Noise of running water
Possible Causes: Back flow of liquid in the refrigerant circulation
Malfunction: A fine mist comes from the air outlet
Possible Causes: This occurs when the air in the room becomes very cold, for example in the COOLING or DEHUMIDIFYING/DRY modes
Malfunction: A strange noise can be heard
Possible Causes: This noise is made by the expansion or contraction of the front panel due to variations in temperature and does not indicate a problem.
Malfunction: Insufficient airflow, either hot or cold
Possible Causes:
- Inappropriate temperature setting..
- Air inlet or outlet of indoor or outdoor unit has been blocked.
- Air filter is blocked.
- Fan speed set at minimum.
- Other sources of heat in the room.
- No refrigerant

Malfunction: The appliance does not respond to commands
1 Comment. Leave new
Good morning.
What is the cause of E3 which is indoor fan speed has been out of control?