Koppel Air Conditioner Error Codes

AC BrandsKoppel

Koppel Super Inverter AC Error Codes;

Koppel Air Conditioner Error Codes
Koppel Air Conditioner Error Codes
Error CodeProblem
E0Indoor unit EEPROM parameter error
E1Indoor / outdoor units communication error
E2Zero-crossing signal error
E3Indoor fan speed has been out of control
E4Open circuit or short circuit of indoor room temperature T1
E5Open circuit or short circuit of evaporator coil temperature T2 sensor
ECRefrigerant Leakage Detection
F1Open circuit or short circuit of outdoor ambient T4 temperature sensor
F2Open circuit or short circuit of condenser coil temperature T3 sensor
F3Open circuit or short circuit of compressor discharge T5 temperature sensor
F4Outdoor unit EEPROM parameter error
F5Outdoor fan speed has been out of control
P0IPM malfuntion of IGBT over-strong current protection
P1Over voltage or over low voltage protection
P2High temperature protection of compressor top diagnosis and solution
P4Inverter compressor drive sensor

EEPROM parameter error diagnosis and solution E0/F4:

EEPROM parameter error diagnosis and solution E0/F4
EEPROM parameter error diagnosis and solution E0/F4

Error Signals On The Display

In case of error, the display on the indoor unit shown the following error codes

Error Code: E 1

RUN lamp: flashes once

Description of the trouble: The fault of indoor temperature sensor

Error Code: E 2

RUN lamp: flashes twice

Description of the trouble: The fault of indoor pipe temperature sensor

Error Code: E 6

RUN lamp: flashes 6 times

Description of the trouble: Malfunction of indoor fan motor.


Koppel Super Inverter AC Error Codes
Koppel Super Inverter AC Error Codes

Koppel AC Troubleshooting

Malfunction: The appliance does not operate 

Possible Causes:

  1. Power failure/plug pulled out
  2. Damaged indoor/outdoor unit fan motor
  3. Faulty compressor thermomagnetic circuit breaker
  4. Faulty protective device or fuses.
  5. Loose connections or plug pulled out
  6. It sometimes stops operating to protect the appliance.
  7. Voltage higher or lower than the voltage range
  8. Active TIMER-ON function
  9. Damaged electronic control board

Malfunction:  Strange odour

Possible Causes: Air filter dirty

Malfunction:  Noise of running water

Possible Causes: Back flow of liquid in the refrigerant circulation

Malfunction:  A fine mist comes from the air outlet

Possible Causes: This occurs when the air in the room becomes very cold, for example in the COOLING or DEHUMIDIFYING/DRY modes

Malfunction:  A strange noise can be heard

Possible Causes: This noise is made by the expansion or contraction of the front panel due to variations in temperature and does not indicate a problem.

Malfunction:  Insufficient airflow, either hot or cold

Possible Causes:

  • Inappropriate temperature setting..
  • Air inlet or outlet of indoor or outdoor unit has been blocked.
  • Air filter is blocked.
  • Fan speed set at minimum.
  • Other sources of heat in the room.
  • No refrigerant
Koppel Air Conditioner Remote Control
Koppel Air Conditioner Remote Control

Malfunction:  The appliance does not respond to commands

1 Comment. Leave new

Leave a Reply

Your email address will not be published. Required fields are marked *

Fill out this field
Fill out this field
Please enter a valid email address.
You need to agree with the terms to proceed

You May Also Like

lloyd ac error codes
Lloyd Air Conditioner Error Codes
klimaire ac error codes
Klimaire Air Conditioner Error Codes

Subscribe to our Youtube Channel

Must Read

Menu