Danby AC Error Codes

AC BrandsDanby

Danby AC Error Codes and Troubleshooting Method

Occasionally, a problem may arise that is minor in nature, and a service call may not be necessary. Use this troubleshooting guide for a possible solution.

Error CodesProblem
E1Error with the coils temperature sensor.
E2Error with the indoor temperature sensor.
E4Frost protection: the temperature of the coil is too low and the A/C shuts down to prevent excess frost build-up. When the temperature increases to 8°C (46.4°F), the protective setting is released and the previous setting is applied.
FtTank is full - Connect the drain hose and drain the collected water away. If error repeats, call for service.
P1Bottom tray is full - Connect the drain hose and drain the collected water away. If error repeats, call for service.
LtLow Temperature. The unit will defrost. The appliance will start again once defrosting is complete
PFProbe failure, call for service

Problem: Unit does not start when pressing on/off button

Possible Cause:

  1. P1 appears in the display window
  2. Room temperature is lower than the set temperature. (Cooling mode)

Solution:

  1. Drain the water in the bottom tray.
  2. Reset the temperature.

Problem: Not cool enough

Possible Cause:

  1. Check the windows and doors in room maybe not closed.
  2. There are heat sources inside the room.
  3. Exhaust air duct is not connected or blocked.
  4. Temperature setting is too high.
  5. After this happens check air filter maybe blocked with dust.

Solution:

  1. Make sure all the windows and doors are closed.
  2. Remove the heat sources if possible.
  3. Connect the duct and make sure it can function properly.
  4. Decrease the set temperature.
  5. Clean the air filter.

Problem: Noisy or vibration

Possible Cause: The ground is not level or not flat enough.

Solution: Place the unit on a flat, level ground if possible.

Problem: Gurgling sound

Possible Cause: The sound comes from the flowing of the refrigerant inside the air conditioner

Solution: It is normal

Problem: Power shut off at Heating mode

Possible Cause: The automatic over heat protection function. When the temperature at the air outlet exceeds 70°C/158°F, the device wi ll stop.

Solution: Switch on again after the unit has cooled down.

Danby Portable AC Remote Control
Danby Portable AC Remote Control

Warning

Be sure the electrical service is adequate for the model you have chosen. This information can be found on the serial plate, which is located on the side of the cabinet and behind the grille.

• Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.

• Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle.

• Ensure the receptacle is accessible after the unit installation.

Danby Portable Air Conditioner Parts
Danby Portable Air Conditioner Parts

How to Fix Danby Ac Error Code P1?

When the water level of the bottom tray reaches a predetermined level, the unit beeps 8 times, the digital display area shows P1. At this time the air conditioning/dehumidification process will immediately stop. However, the fan motor will continue to operate (this is normal). Carefully move the unit to a drain location, remove the bottom drain plug and let the water drain away (Fig.24). Restart the machine until the P1 symbol disappears. If the error repeats, call for service.

During dehumidifying modes, remove the drain plug from the back of the unit, install the drain connector (5/8” universal female connecter) with 3/4” hose (locally purchased). For the models without a drain connector, just attach the drain hose to the hole. Place the open end of the hose directly over the drain area in your basement floor. Please refer to Fig.22 & 23.

NOTE: When operating or draining water always protect carpeting or floors from possible water spillage.

Leave a Reply

Your email address will not be published. Required fields are marked *

Fill out this field
Fill out this field
Please enter a valid email address.
You need to agree with the terms to proceed

You May Also Like

delonghi ac error codes
Delonghi AC Error Codes
daikin ac error codes
Daikin AC Error Codes

Subscribe to our Youtube Channel

Must Read

Menu